<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>4025</ErrorNumber>
<ErrorFamily>Messaging</ErrorFamily>
<ErrorMessage>
MSG: Configure bin command received while one was already active
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An attempt has been made to open or load a bay when the recorder already has an open or load bay
command active.
</text></DescriptionText>
<DescriptionText><text>
Unless the diagnostic monitor interface has recently been used to open or load bays, this error indicates that
the workstation and recorder are no longer synchronized and should be rebooted.
</text></DescriptionText>
<DescriptionText><text>
If the diagnostic monitor is being used to open or load bays, make sure that any open or load command has
finished (i.e. all bays are locked) before attempting a new bay command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Re-boot the workstation and recorder.  If this error occurs more than once, report the details to Creo
service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Recorder and workstation are no longer synchronized.
</Cause>
<Cause>
Diagnostic monitor open or load bay command active when another bay command issued.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:23 2008 PST
</Updated>
<Links>
</Links>
</Error>